400 008 3510
如果您有任何疑问请及时与我们联系!产品优势: Modular design and N+X parallel redundancy technology, high-performance DSP processor, intelligent management of battery charging and discharging, and rich remote monitoring means
生产能力: 50 sets/month
应用领域: DR and CT medical equipment, small and medium-sized data centers, precision electrical instruments for education and scientific research, merchant cash registers and POS equipment, oil fields and industrial and mining fields.
The importance of voltage regulators and UPS power supply for medical equipment
1. Three in three out pure online dual conversion product, supporting 380/400/415V, 50/60Hz power grid system, providing the best power supply quality and load protection.
2. Super load adaptability, super overload and short circuit capacity.
3. Ultra wide input voltage and frequency range, suitable for harsh power grid environment, and suitable for the access of various oil fired generators.
4. The input power factor is up to 0.99, the input harmonic current is less than 3%, and the overall efficiency is more than 95%. It is green, environmentally friendly, efficient and energy-saving.
5. DSP full digital control realizes the digital control of all power conversion links of rectification, inverter, charging and discharging.
6. 7-inch LCD color touch screen and EPO emergency judgment button, with a large capacity of historical record storage space; ECO efficient energy-saving mode.
7. Intelligent battery management scheme extends battery life.
8. The system adopts modular design, with stable and reliable performance.
9. All fans in the system adopt redundant design, which greatly improves the reliability of the system.
10. The panel is equipped with EPO emergency shutdown button.
11. Ultra long MTBF (>200000h), ultra low MTBF (<0.5h).
12. Rich options: dust-proof net, SNMP network communication card, lightning protection module, battery temperature compensator, mobile phone short message alarm.
13. All circuit boards adopt the three prevention process.
14. It can replace the traditional module machine and save the high cost of module cabinet.
The importance of voltage regulators and UPS power supply for medical equipment
1.Brand: Kingwall
2. Specification and model: 3C3-30KVA, 3C3-40KVA, 3C3-60KVA, 3C3-80KVA, 3C3-100KVA, 3C3-120KVA, 3C3-160KVA
3. Capacity: 30KVA, 40KVA, 3C3-60KVA, 80KVA, 100KVA, 120KVA, 160KVA
4. Input mode: 3P4W ± 25%
5. Rated voltage: 380V/400V/415V
6. Voltage range of main circuit:+20%~-20% full load, -20%~-40% load capacity, linear derating between 100% and 70%
7. Input frequency: 50Hz/60Hz ± 5% (optional ± 10%), default 50Hz ± 5%
8. Power factor:>0.95
9. Bypass input voltage: 380V/400V/415V
10. Bypass input range: -50%~+20%
11. Output voltage accuracy: ± 1% (balanced load)
12. Dynamic voltage transient: 2% (0~100% load change)
13. Voltage distortion rate: pure sine wave. ≤ 2% under resistive load, ≤ 3% under nonlinear load
14. Power factor: 0.8/0.9
15. Frequency tracking range: 50/60Hz ± 3Hz settable
16. Output frequency precision: 50/60Hz ± 1% (inverter status)
17. Output phase accuracy: 120 °± 1 °
18. Voltage unbalance: balance load<1%; 50% unbalanced load<3%; 100% unbalanced load<5%
19. Frequency tracking rate: 0.5Hz/s to 5Hz/s can be set
20. Peak ratio of output current: 5:1
21. Output overload capacity: ≥ 125%, switch to bypass after 10 minutes; ≥ 150%, switch to bypass after 15 seconds
22. Bypass overload capacity: 150% long-term operation, 150%<load<180% working time longer than 1 minute, load>180% working time longer than 100ms
23. System normal mode: 95%
24. System economic mode: 99%
25. Battery mode efficiency: 95%
26. Battery configuration: 12V32
27. Display: LCD+LED touch screen+keyboard
28. Insulation resistance:>2M (500VDC)
29. Insulation strength: (input/output to ground) 2820Vdc leakage current is less than 3.5mA1 minute, no arcing
30. Surge protection: meet the requirements of Class IV installation position specified in IEC60664-1, that is, the ability to withstand 1.2/50us-8/20us mixed wave shall not be less than 6KV/3KA
31. Protection grade: IP20
32. Communication interface: RS232RS485 dry contact SNMP card EPO generator interface
33. Wiring mode: support upper and lower incoming lines
34. Noise (dB):<55dB (1m)
model | capacity | External dimensionsW*L*H(mm) | weight(kg) |
---|---|---|---|
3C3-30KVA | 30KVA | 250*815*826 | 200 |
3C3-40KVA | 40KVA | 300*815*1000 | 250 |
3C3-60KVA | 60KVA | 410*750*940 | 340 |
3C3-80KVA | 80KVA | 360*790*900 | 460 |
3C3-100KVA | 100KVA | 800*600*1500 | 580 |
3C3-120KVA | 120KVA | 800*600*1500 | 680 |
3C3-160KVA | 160KVA | 800*600*1500 | 750 |
The above data is for reference only。
1. Ambient temperature: 0 ℃~40 ℃
2. Relative humidity: 0~95% (no condensation)
3. Altitude: not more than 2000m
4. Installation site: no gas, steam, dust, dirt and other explosive and corrosive media with serious insulation