400 008 3510
如果您有任何疑问请及时与我们联系!产品优势: Automatic voltage stabilization, high-precision voltage stabilization, advanced DSP digital control technology, active input power factor correction (PFC), wide input voltage, zero switching, frequency adaptive system, powerful expansion function, and added AC filter can effectively eliminate ultrasonic artifacts and avoid wave shaped radiation interference on two-dimensional echo images.
生产能力: 200 sets/month
应用领域: High end color ultrasound, biochemical instrument, blood cell instrument, blood sampler, chemiluminescence instrument, contrast instrument, patient monitoring equipment and other low-power medical equipment and instruments, as well as office computers and network equipment.
The importance of voltage regulators and UPS power supply for medical equipment
1. Pure sine wave output, battery start
2. LCD screen displays load size, battery capacity, mains mode/battery mode/bypass mode and fault indication
3. With output short circuit protection and overload protection
4. With lightning surge protection
5. Full time lightning protection, noise and surge protection
6. CPU design, self detection function and high reliability
7. It can be matched with power monitoring software "electronic management expert" to realize remote monitoring
8. Intelligent battery management system extends battery life
9. The network interface port adds automatic and safe system shutdown
10. SNMP accessory slot for power network management as required
11. Automatically adjust too high or too low voltage
12. Network level line adjustment to prevent signal burrs
13. AC filter is added to effectively eliminate ultrasonic artifacts and avoid wave shaped radiation interference on two-dimensional echo images
The importance of voltage regulators and UPS power supply for medical equipment
1.Brand: Kingwall
2.Specification and model: C1K/C2K/C3K/C6K/C10K
3. Capacity: 1KVA/2KVA/3KVA/6KVA/10KVA
4. Input wiring: 3KVA and below are equipped with plug power lines, and 6KVA and above need to be equipped with power line terminal wiring
5. Input voltage: 176V~276V
6. Input frequency: 46 ~ 54Hz
7. Output voltage: 220V ± 1%
8. Input frequency: 50 (1 ± 0.2%) Hz (battery mode)
9. Current peak ratio: 3:1
10. Display description: LCD screen displays load size, battery capacity, mains mode/battery mode/bypass mode and fault indication
11. Output waveform: sine wave
12. Charging time: 4 hours to 90%, 9 hours for 6KVA or above
13. Standby time: 10~15 minutes for full load, double for half load
14. Conversion time: 0 seconds
15. Overload capacity: 110%~130% 30min to bypass, and more than 130% 1min
16. Communication interface: RS-232, optional SNMP
model | capacity | External dimensionsW*L*H(mm) | weight(kg) |
---|---|---|---|
C1K | 1KVA/0.8KW | 145*280*220 | 10 |
C2K | 2KVA/1.6KW | 145*400*220 | 18 |
C3K | 3KVA/2.4KW | 190*420*320 | 28 |
C6K | 6KVA/4.8KW | 190*370*690 | 60 |
C10K | 10KVA/8KW | 190*440*690 | 71 |
1. Ambient temperature: 0 ℃~40 ℃
2. Humidity: 0~90%
3. Altitude: not more than 2000m
4. Installation site: no gas, steam, dust, dirt and other explosive and corrosive media with serious insulation
5. Installation site: no serious vibration or turbulence
6. Other instructions: Any special use conditions that do not meet the above provisions shall be determined by the user unit and our factory through consultation